What are the RO Plant Specifications for different capacities?
“Netsol Water” is a corporation that offers design, fabrication, installation, and maintenance services of Commercial and Industrial RO Plants, all under one roof.
A reverse osmosis plant is a system that performs the reverse osmosis process. By pushing water or wastewater over a membrane, reverse osmosis is a typical method for purifying or desalinating polluted water.
RO Plant comes in different LPH ranges as follows:
100 LPH RO Plant Specification
The Netsol Model of 100 lph RO Plant is a top-of-the-line product with excellent quality and performance. This model is designed for long-term use, reliable and simple operation, and great efficiency. It has a faultless design that does not cut corners when it comes to quality or design requirements. This model has the following features in addition to a fully automated control panel:
S. No. |
Parameter |
Specification |
1 |
Purification capacity |
100±20* Litres per hour * |
2 |
Max Duty Cycle |
500-700 litres per day |
3 |
Membrane |
3 No’s |
4 |
RO Membrane |
300 GPD (3 units) |
5 |
Solenoid Valve |
220 V |
6 |
Minimum Inlet Water Pressure |
0.3 kg/sq. cm |
7 |
Maximum Inlet water Pressure |
2 kg/sq. cm |
8 |
Input Voltage |
160-300V AC ( 50Hz) |
9 |
Operating Voltage |
24V DC |
10 |
Input water Temperature |
Min 5 Celsius & Max 50 Celsius |
11 |
Total Dissolved Solids (TDS) |
Up to 2000 ppm |
12 |
Total Hardness |
500 ppm (max) |
13 |
Rejection of TDS |
Up to 95% |
14 |
Recovery |
Up to 25% |
15 |
Dimensions (mm) |
W 550 x D 300 x H 900 |
16 |
Net Weight |
32 kgs. |
17 |
Power rating |
250 W |
200 LPH RO Plant Specification
The Netsol Model of 200 lph RO Plant is a top-of-the-line product with excellent quality and performance. This model is designed for long-term use, reliable and simple operation, and great efficiency. It has a faultless design that does not cut corners when it comes to quality or design requirements. This model has the following features in addition to a fully automated control panel:
S. No. |
Parameter |
Specification |
1 |
Purification capacity |
200±20* Litres per hour * |
2 |
Max Duty Cycle |
2000 Litre per day |
3 |
Membrane |
2 |
4 |
RO Membrane |
4” Dia. 40” Length (3 units) |
5 |
Minimum Inlet Water Pressure |
0.5 kg/sq. cm |
6 |
Maximum Inlet water Pressure |
2.5 kg/sq. cm |
7 |
Input Voltage |
220/1-phase/50hz |
8 |
Operating Voltage |
32V DC |
9 |
Input water Temperature |
Min 5 Celsius & Max 50 Celsius |
10 |
Total Dissolved Solids (TDS) |
Up to 3000 ppm |
11 |
Total Hardness |
1200 ppm (max) |
12 |
Rejection of TDS |
Up to 95% |
13 |
Recovery |
Up to 25% |
14 |
Space Requirement |
4900 mm (W) x 1100mm (D) x 1711 mm (H) |
15 |
Net Weight |
- |
16 |
Power rating |
1.5 kW |
500 LPH RO Plant Specification
The Netsol Model of 500 lph RO Plant is a top-of-the-line product with excellent quality and performance. This model is designed for long-term use, reliable and simple operation, and great efficiency. It has a faultless design that does not cut corners when it comes to quality or design requirements. This model has the following features in addition to a fully automated control panel:
S. No. |
Parameter |
Specification |
1 |
Purification capacity |
500±40* Litres per hour * |
2 |
Max Duty Cycle |
10000 Lt per day |
3 |
Membrane |
1 |
4 |
RO Membrane |
2 |
5 |
Voltage |
220 V |
6 |
Material of Construction |
Stainless Steel |
7 |
Input water Temperature |
<45 degree C |
8 |
Total Dissolved Solids (TDS) |
<100 PPM |
9 |
Total Hardness |
<50PPM |
10 |
Rejection of TDS |
Upto 97% |
11 |
Net Weight |
350 kg |
1000 LPH RO PlantSpecification
Netsol's Model of 1000 lph RO Plant is a Class Product with Ideal Quality, Design, and Technical Aspects. This model is built for longer life, compact, stable, and easy operation, and high end efficiency. It has a flawless design that does not scrimp on quality or design standards. This model includes a completely automated control panel, as well as the following features:
S. No. |
Parameter |
Specification |
1 |
Purification capacity |
1000 ±40* Litres per hour * |
2 |
Max Duty Cycle |
100000 Lt per day |
3 |
Membrane |
2 No’s |
4 |
RO Membrane |
1 |
5 |
Minimum Flow Rate |
3m3/hr |
6 |
Maximum Inlet Flow Rate |
0.5 m3/hr |
7 |
Material of Construction |
Stainless Steel |
8 |
Operating Voltage |
220V |
9 |
Total Dissolved Solids (TDS) |
<1000PPM |
10 |
Total Hardness |
<100 PPM |
11 |
Rejection of TDS |
Upto 70-80% |
12 |
Recovery |
50-70% |
13 |
Power rating |
5KW |
Reverse osmosis water can be used for a variety of things, including desalination, wastewater treatment, pollutant concentration, and dissolved mineral reclamation.