How do I maintain reverse osmosis system?

RO Plant treatment system service and maintenance plan is a cost-effective, interference-free way to ensure that the system is performing to its full potential. Netsol Water Solutions provides maintenance and services to guarantee that the water treatment systems are performing at their best.

A preventative maintenance plan for your treatment system is a cost-effective and trouble-free approach to ensure that it is performing at its best!

Our highly qualified service professionals are experts in the operation, maintenance, and troubleshooting of high purity RO treatment systems, and will ensure that your system is being monitored and maintained on a regular basis. After each service visit, you will receive a report on your system's performance as well as any recommended action items.

RO (Reverse Osmosis) systems contain three, four, or five filter stages. We'll go over some general maintenance tips that apply to most RO units.

1: To begin, water passes through a pre-filter to safeguard the sensitive RO membranes. Dirt, silt, sand, and other sediments are filtered out by this pre-filter cartridge. The Micron Filter should be updated at least once a year.The pre-filter might foul or become clogged if it is not properly maintained or changed on a regular basis.

2: A carbon filter, which is designed to eliminate chlorine and other taste or odour pollutants, is usually used next. Because chlorine can damage the RO membrane, this is critical. Also, once in a year, this carbon filter should be updated.

3: The separation technique of reverse osmosis (RO) employs pressure to drive water through a membrane. The contamination is retained on one side of the membrane while the pure solvent (water) passes through to the other.

The lifespan of the filter and membrane will vary depending on local water conditions and usage.

4:  At the end of the cycle, a carbon filter step is frequently added to "polish" the water. This stage eliminates any leftover flavour or odours, resulting in excellent drinking water. Every 6-9 months, the carbon filter should be replaced.

Apart from these steps, the following should be kept in mind!

1: Dosing chemical for anti-scaling (As per requirement);

2: Pump for raw water (checking/servicing if necessary);

3: High-pressure pump (if necessary, check/service);

4: On-site monitoring of membrane flow rate and TDS;

RO systems should be maintained on a regular basis for maximum efficiency.

S. No.

Description of item

Approximate market cost

Frequency of replacement

1.

Membrane

Rs.22,170/-

1 Year (normally)

2.

Micron Filter

Rs. 260/-

During every servicing

i.e. 6 times annually

3.

Anti-scalant Chemical

Rs. 6,620/-

1 Year (normally)

 

 

Is RO system required to be cleaned?

Yes, a sanitization and recharge of the system should be done once a year. This maintenance can be done by a local water treatment professional or by consulting the owner's manual for your RO system.

In India, get the best industrial and commercial RO Plants!

Reverse osmosis is used as a pre-treatment or post-treatment in Industrial facilities and for potable use in commercial facilities.

Enquire Now

Related Blog List

  • What are the various solids present in waste water
  • What is the source of Foam in Aeration basins
  • Safe measures to re use oil waste and its disposal
  • Why get Netsol’s Reverse Osmosis Plant
  • Importance of Commercial RO plants in Universities
  • View All Blogs

Popular Tags

  • Sewage Treatment Plant
  • Sewage Treatment Plant Manufacturer
  • Effluent Treatment Plant
  • Effluent Treatment Plant Manufacturer
  • Industrial RO Plant
  • Commercial RO Plant Manufacturer
  • Water Treatment Solutions
  Thank you for Signing Up
Please correct the marked field(s) below.
Join Hands Now!
Get all the details on priority basis.
It's free!
1,true,6,Contact Email,2 1,false,1,First Name,2 1,false,1,Last Name,2
Join Us
  Thank you for Signing Up
Please correct the marked field(s) below.
1,true,6,Contact Email,2 1,false,1,First Name,2 1,false,1,Last Name,2
Netsol Water NewsLetter - Form
Netsol Water NewsLetter - Form
Netsol Water is a water and wastewater treatment company in Delhi NCR, India that designs, and manufactures ace machines to save the earth and its resources, especially water.

About Us

  • Why Choose Us
  • Disclaimer
  • Terms and conditions
  • Sitemap
  • Contact us

Resources

  • News
  • Knowledge Center
  • Gallery
  • Manufacturing: Plot No.- 217,Udyog Kendra-2, Ecotech-3,Greater Noida, Uttar Pradesh, India

Contact us

  • J-176, SECTOR-41, NOIDA, Gautam Buddha Nagar, Uttar Pradesh,India, 201301(Reg.)
  • Call Us: +91 9650608473/9650795306
  • Email: info@netsolwater.com
COPYRIGHT © 2022 NETSOL WATER SOLUTIONS PVT. LTD. - WATER TREATMENT COMPANY DELHI/NCR. ALL RIGHTS RESERVED.
ASR Search EngineaWeb Llist .org Addurl.nuPicktu Directory