How to optimize RO Plant design with process modeling?
Reverse osmosis is the process of exerting pressure over the osmotic pressure on a membrane to force a solvent through an area of high solute concentration and into a region of low solute concentration. This is the opposite of the usual osmosis process, which occurs naturally when no external pressure is applied and involves the passage of solvent through a membrane from a region of low solute concentration to an area of high solute concentration. Since the membrane in this case is semipermeable, only solvent can pass through, but not solute.
The separation takes place in a dense polymer barrier layer that is present in the membranes used in reverse osmosis systems. Since reverse osmosis does not occur naturally, it must be produced by applying pressure to the high solids water in order to force it through the membrane. Fresh and brackish water requires pressure between 8 and 14 bar, while seawater requires pressures between 40 and 70 bar, as the natural osmotic pressure of seawater is 24 bar (350 psi), which must be overcome.
Design factors:
The Crossflow filtering method is used in Fluid Systems RO Plants to remove particulates during the filtering process by using a portion of the feed water as a wash or reject stream.
Temperature and pressure are the two key factors that affect a RO plant's product flow. The features of the feed water have a limit on system recovery (product divided by feed), although recycle stream can be used to regulate it. The percentage of dissolved solids given to the membrane determines the quality of the final product. Product recovery and economic balance between quality should be maintained. High recoveries make the system run more effectively and cut down on waste, but they also raise the concentration of dissolved solids in the system, which lowers quality.
Reverse Osmosis Plants are unable to supply all of the water that is supplied to them. Only a portion of the incoming water is converted into final product water during operation since some of it is required to wash down the membrane. Wastewater is referred to as concentration, or reject, whereas purified water is referred to as product. The recovery, which is determined by the membrane and overall design factors for the RO plant, is the percentage of water that is provided as a finished good.
Optimization of RO plant design considerations:
Step 1: Feed water source
The first consideration when optimizing the design of a reverse osmosis system is the feed water source. Although industrial or municipal wastewater is a possibility, surface or well water is often the water source for brackish water membranes (BWRO). It is crucial to investigate where the municipality gets its water, even if the source is municipally treated water. As the features of the water source will affect the RO membrane operation, this enables the best system design.
The water supply suggests that scaling and fouling are possible. The buildup of solids on the feed spacer or membrane surface is referred to as fouling. On the concentrate side of the membrane, scaling is a chemical reaction where dissolved particles are precipitated out of the feed water.
Step 2: Determine the flow type
There are two forms of flow. Plug flow and concentrate recirculation. Continuous plug flows are usually preferred. Feed water enters the system once during plug flow.
Feed water travels through the membrane components, creating concentrated and permeate water. To maximize the quantity and effectiveness of permeate in all systems, however, we occasionally send concentrated water back to the water source that it came from. Recirculation of concentrates is this flow type. It depends on the TDS level in concentrated water, the rate of membrane recovery, and the kind of membrane. So, another crucial factor in designing a reverse osmosis plant is flow type.
Step 3: Determine the Membrane and Membrane Type
A reverse osmosis system is designed with components that are chosen based on the feed water salinity, feed water fouling propensity, needed rejection, and energy requirements. The feed source is the first element that needs to be taken into account. BW types of RO membranes must be chosen if the feed is brackish water. SW types of RO membrane must be taken into consideration if the feed is seawater. TDS ranges from 1000 to 15000 mg/l for brackish water and is greater than 15000 mg/l for seawater. Mg/l and ppm are the same unit, however.
Step 4: Selection of design flux
Reverse osmosis plants are designed by water treatment firms using a certain permeate flow rate and recovery rate. Recovery rate is the percentage of feed water that is converted to permeate processed water.
The tendency of the feedwater to scale and foul is the aspect that has the biggest impact on the design of the membrane system.
To reduce the rate of fouling and to assist prevent mechanical damage, a membrane system should be built so that each component runs within a range of advised operating conditions. These element operating circumstances are constrained by:
• maximum recovery
• maximum permeate flow rate
• minimum concentrate flow rate
• maximum feed flow rate
Step 5: Calculation of module number
In order to compute the module number, we need to know:
• Permeate flow (Qp) (m3/day)
• Membrane active area, (Ae) (m2)
• Design flux, (f) (L/m2.h)
Permeate flow measures the amount of water the machine can handle daily. You can obtain the membrane active area from the supplier of RO membranes.
Step 6: Calculation of Pressure Vessel number (Nv)
Total number of pressure vessels needed = (total number of modules) / (number of modules in a pressure vessel).
For large systems, 6-element vessels are accepted, but vessels with up to 8 elements are available. Smaller vessels may be chosen for systems that are more compact or smaller.
Step 7: Balance the Permeate Flow Rate
The final module of a system often has a lower permeate flow rate than the initial parts. Therefore, the pressure decrease in the feed channel and the rise in osmotic pressure from the feed to the concentrate are to blame for this.
The ratio of the first element's permeate flow rate to the last element's permeate flow rate might increase dramatically in certain circumstances. These circumstances include:
• The high system recovery
• High feed salinity
• Low-pressure membranes
• High water temperature
• New membranes
Conclusion:
Reverse osmosis is, in general, a dependable and user-friendly technique. The feed water supply and user-specific needs, such as permeate quality and maintenance capabilities, can be taken into account to provide optimal reliability. While some systems are offered with the lowest capital cost, a high-quality system developed by skilled and experienced engineers can accomplish less maintenance, longer membrane life, and reduced cleaning frequency.